IP65 LED Garden light 80w garden lighting Park garden lamp
SLT07 Series LED Garden light
SLT07 Series LED Garden light
T07 assembly instructions
Remove the stainless steel presser from the support bar
Attach the two support rods to the circular joint (M6*20MM)
Install the support rod assembly installed in the previous step on the circular lamp
The finished effect is shown in the picture above
Hold the wire with a stainless steel sheet
Cover the middle joint with a circular cover
Electrical Characteristics
Input Voltage: AC100-240V
50/60Hz PF: >0.9
Power Efficiency: ≧0.90
Features
• IP66 waterproof/dust proof/explosion proof/IK09.
• Aluminum shape good at heat dissipation.
It can also be installed vertically
• Philips SMD 3030 Ra>70/SDCM<6
• 100,000 times switching cycle before failure
• Total harmonic distortion(THD)<10%
• Excellent post light control design, the whole lamp can achieve T II-M, T III-M,That's our advantage
• Pass 3G vibration test
Application
Garden light
It is mainly applied to branch road, factory, school, garden, various residential communities and courtyards. The installation height is 4-8m and the installation torque is 16Nm.
Product Dimension
Model NO. | Size L(mm) | Size W(mm) | Size H(mm) | Support pole diameter |
T07 | 450 | 450 | 523.5 | 76/60 |
Parameter
Model NO. | Power(W) | Light Source | LED QTY (PCS) | Lens(PCS) | CCT(K) | Lumen(km/h) | CRI |
T07-30W | 30 | 3030 | 64 | 4 | 4000k | 130 | >70 |
T07-40W | 40 | 3030 | 64 | 4 | 4000k | 130 | >70 |
T07-50W | 50 | 3030 | 64/96 | 4/6 | 4000k | 120/135 | >70 |
T07-60W | 60 | 5050 | 96 | 6 | 4000k | 130 | >70 |
T07-80W | 80 | 3030 | 108 | 9 | 4000k | 130 | >70 |
T07-100W | 100 | 3030 | 144 | 9 | 4000k | 130 | >70 |
T07-120W | 120 | 3030 | 144 | 9 | 4000k | 130 | >70 |
T07-150W | 150 | 3030 | 216 | 9 | 4000k | 130 | >70 |
Erp Technical Specification
Item | Symbol | specification/Data |
Color Index | CRI | Ra>70 |
Luminous Efficacy | lm/W | 120--140 lm/W |
Energy efficiency Class | / | A++ |
Color consistency in level | / | Max.6SDCM |
THD | / | <15% |
Starting Time | S | <0.5S |
Switching cycle before failure | / | >100,000times |
Premature failure rate@1000h | / | 0 |
Lifespan | H | >50000Hrs |
Installation way
Installing steps
Turn off the power before installing.
Make sure the model, rated voltage and wattage are the same with the design parameters.
Check the wire specification, Connect the wire, Through the waterproof connector, connect the L/N wire of the street lamp to L/N wire of the city electricity.
1. Put the light into the light stem.
2. Fix the screw of handle.
3. Check the installing of the light whether level or not .
4. Adjust the angle into which needed
5. Check the the handle screw fixed or not, if loose, should make it tightly, torque is 16NM
Packing:
Attention
This specification is for reference only,we reserve the right to change without notice.